E 2.2.1.1 Transformatory trójfazowe 300W

Zapytaj o produkt +

Opis

The experiments are carried out using transformers on training panels in panel frames.

Objectives

  • Protective measures and electrical safety
  • Set-up of power generation systems according to circuit diagrams
  • Use of commercial measuring instruments, hand-held multimeters, oscilloscopes, measuring interfaces

Transformers are magnetically coupled systems used for transforming AC voltages or matching impedance. Transformers can therefore be used primarily for measurement or generation of electric power. These practical exercises study exclusively transformers used in energy generation. Transformer power ratings can range from a few mVA up to several MVA. The size and design also have an important effect on the transformer ratings. Transformers are regarded as electrical machines even though they contain no moving parts. The windings of three-phase transformers can be connected in a variety of circuit configurations.

This individual equipment set allows for measurement of three-phase transformers under load (resistive, inductive, capacitive).

Students carry out the experiments as specified in the printed manual. Hand-held multimeters are used to measure the characteristics of the transformers. Either an oscilloscope with an isolating amplifier or Sensor-CASSY 2 can be used in order to display the phase-shift between phase winding voltages.

The target group is made up of commercial apprentices and students of power engineering. The course offers experiments at an intermediate level for vocational colleges and undergraduate level.

Topics

  • Voltage equations and equivalent circuits
  • Measurement without load, with load and with a short circuit
  • Determination of self-inductance, magnetic coupling and leakage
  • Losses, changes in voltage and efficiency
  • Circuits and vector groups for three-phase transformers
  • Simultaneous operation of multiple three-phase transformers

Similar to illustration

733 90 Three-phase transformer 0.3 1
732 40   Resistive load 0.3 1
732 41 Capacitive load 0.3 1
732 42   Inductive load 0.3/1.0 1
531 282   Multimeter Metrahit Pro 3
727 12   Power factor meter 1
575 213   Oscilloscope 40 MHz, two-channel, analogous 1
575 231   Probe 100 MHz, 1:1 / 10:1 2
735 261   Isolation amplifier, four channel 1
Alternative measuring equipment which can be used instead of isolating transformer, oscilloscope and probes:
524 013S   Sensor-CASSY 2 Starter 1
524 013   Sensor-CASSY 2 1
726 09   Panel frame T130, two-level 1
725 442DG Three-phase voltage supply 400 V/2.5 A 1
500 59   Safety bridging plugs, black, set of 10 2
500 591   Safety bridging plugs, yellow/green, set of 10 1
500 851   Safety connecting leads, 32 A, set of 32 1
500 852   Safety connecting leads, 32 A, yellow/green, set of 10 1
569 2001L   LIT: Transformers (in German) T 10.1 1
569 2002   * LIT: Transformers (in English) T 10.1 1
569 2001S   LIT: Transformers (in German) T 10.1 1
additionally required: PC with Windows XP/Vista/7/8

Articles marked with * are not essential, we do however recommend them to carry out the experiment.

 

Marka

Leybold

Firma produkuje zestawy edukacyjne do kształcenia akademickiego oraz szkolenia zawodowego z zakresu fizyki, chemii, biologii oraz elektroniki, elektrotechniki, automatyki, telekomunikacji, maszyn elektrycznych, odnawialnych źródeł energii i fotoniki, jest częścią grupy LD Didactic.