Opis
The experiments are carried out on training panels in panel frames.
Objectives
- Protective measures and electrical safety
- Finding and analysing faults in phase angle control circuits
- Use of commercial measuring instruments: hand-held multimeters and oscilloscopes
The fault simulator is a standard dimmer for a resistive load (Pmax. = 1.2 kW) pre-calibrated for minimum value. Various measuring points allow for systematic troubleshooting. There are a total of 20 faults which can be switched and which are of the following categories:
- Breaks
- Short circuits
- Wrong components
- Component faults
The faults are activated by slider switches located behind a lockable cover.
The equipment set is designed for student experiments in a laboratory using low voltage (230 V AC). Experiment procedures are provided in a printed manual.
The target group is students in vocational colleges. The experiments are intended as an introduction at a simple level.
Topics
- Investigation of a circuit with some 20 different faults
- Component faults (short circuits, high resistance)
- Breaks in conductors
- High or low-resistance connections within the circuit
- Wrong or missing components (e.g. incorrect values)
735 390 | Fault simulator for phase control | 1 |
505 272 | Bulbs, 230 V/40 W, E14, set of 2 | 2 |
729 09 | Lamp sockets E14, set of three | 1 |
735 190 | Phase control noise filter 3 x 4.5 A | 1 |
501 02 | BNC cable, 1 m | 2 |
531 282 | Multimeter Metrahit Pro | 1 |
735 261 | Isolation amplifier, four channel | 1 |
575 231 | Probe 100 MHz, 1:1 / 10:1 | 2 |
575 230 | Digital storage oscilloscope 722 | 1 |
524 013S | Sensor-CASSY 2 Starter | 1 |
726 09 | Panel frame T130, two-level | 1 |
726 80 | Transformer, 45/90, 3 N | 1 |
500 59 | Safety bridging plugs, black, set of 10 | 1 |
500 851 | Safety connecting leads, 32 A, set of 32 | 1 |
500 852 | Safety connecting leads, 32 A, yellow/green, set of 10 | 1 |
569 071 | LIT: Fault Simulator Phase Control (in German) | 1 |
569 072 | * LIT: Fault Simulator Phase Control (in English) | 1 |
Articles marked with * are not essential, we do however recommend them to carry out the experiment.