Opis
The experiments are carried out using training panels in panel frames along with a DC machine of industrial design.
Objectives
- Protective measures and electrical safety
- Experiment set-up and wiring according to a circuit diagram
- Setting up industrial commutator machines and putting them into operation
- Use of computer-assisted measurement interfaces
This equipment set allows you to set up a modern drive system in order to adjust the speed. The power electronics is implemented in the form of circuits using modular, discrete components. The load used is a DC machine operating without a load. The chopper allows for the speed to be set by limiting trigger angle and for the direction of rotation to be reversed. The trigger response of thyristors to pulse and burst control is investigated along with the resulting effects on the effects on the running characteristics of the machine.
The equipment set is suitable both for student experiments in a lab using low voltage (400 V three-phase) and on a mobile trolley for demonstrations by teachers in a classroom. The experiment procedures are contained in a printed manual.
The target group is made up of commercial apprentices and students of electrical machine construction. The course offers experiments at an intermediate level and also allows for the necessary insight into machine behaviour for scientific interpretation at undergraduate level.
Topics
- Set-up of an H-bridge
- Full-bridge converter
- Reversal of voltage
- Reversal of current
- Setting the speed for DC machines
Similar to illustration
731 86 | DC compound machine 0.3 | 1 |
726 80 | Transformer, 45/90, 3 N | 1 |
734 02 | Reference variable generator | 1 |
726 86 | DC-Power Supply ± 15 V/3 A | 1 |
726 962N | Function generator 200 kHz net | 1 |
735 341 | Control unit PWM/PFM | 1 |
735 346 | IGBT 1000 V/10 A | 4 |
735 02 | Diode, 1000 V/10 A | 1 |
735 065 | Rectifier B6, 3X400 V/10 A | 1 |
735 095 | Capacitors 2x 1000 µF, 385 V | 1 |
735 18 | Fuse threefold super-fast | 1 |
735 190 | Phase control noise filter 3 x 4.5 A | 1 |
531 282 | Multimeter Metrahit Pro | 2 |
575 231 | Probe 100 MHz, 1:1 / 10:1 | 2 |
575 230 | Digital storage oscilloscope 722 | 1 |
731 07 | Shaft end guard 0.3 | 2 |
501 02 | BNC cable, 1 m | 2 |
735 261 | Isolation amplifier, four channel | 1 |
500 851 | Safety connecting leads, 32 A, set of 32 | 1 |
500 852 | Safety connecting leads, 32 A, yellow/green, set of 10 | 1 |
500 59 | Safety bridging plugs, black, set of 10 | 3 |
565 351 | LIT: Power Electronics and Drive Technology, T 12.3.2 (in German) | 1 |
565 352 | * LIT: Power Electronics and Drive Technology, T 12.3.2 (in English) | 1 |
Articles marked with * are not essential, we do however recommend them to carry out the experiment.