Miernik prądu upływu DC ME6300D (0.0mA~300.0mA DC/ 0.30A~6.00A DC)
Opis
Function
|
Measurement of DC leakage current, DC current, Car leakage
|
Power
|
Zn-Mn dry battery,6F22, 9V DC, continuous use for 60 hours
|
Test Mode
|
Clip-on CT, Magnetic modulation
|
Clamp Size
|
25mm×30mm
|
Range
|
0.0mA~6.00A DC
|
Resolution
|
0.1mA DC
|
Accuracy
( 23°C±3°C, below 70%RH)
|
0.0mA~300.0mA DC: ±2%rdg±5dgt
0.30A~6.00A DC: ±2%rdg±5dgt
|
Shield Type
|
Double shielding
|
Display Mode
|
Four digits LCD display
|
Dimension
|
LWH:175mm×70mm×38mm
|
LCD Dimension
|
35mm×21.5mm; display domain:32mm×15mm
|
Sampling Rate
|
About 2 times/s
|
Range Shift
|
0.0mA~6.00A DC Automatically
|
Zero-Adjustment
|
Yes, calibrate zero before measuring
|
Polarity Indication
|
Auto identified and display“—”
|
Test Position
|
Tested wire in the jaw center
|
Line Voltage
|
600V DC
|
USB Interface
|
Data stored in the memory of the meter via USB upload to PC, or on-line monitoring
|
Data Memory
|
99units,FULL blinks when the memory is full
|
Peak Hold
|
Push HOLD without release, the meter will show the peak value during the pushing period
|
Reading Hold
|
DH indicating the reading is hold
|
Out of Range
|
OL indicating the current is out of range
|
Auto Power-off
|
5 Minutes after power on, it will power off automatically to lower the power consumption
|
Battery Voltage
|
Indicating the battery voltage is lower than 7.2V. Then the battery have to be changed
|
Weight
|
120g( including the battery)
|
Working Current
|
20mA
|
Limit Temperature Error
|
-10°C~0°C and 40°C~50°C,within 2%rdg
|
Temperature and Humidity
|
Working : -10°C~50°C,below 80%rh
Storage : -10°C~60°C,below80%rh
|
Insulating Strength
|
AC3700V/rms(between the alloy of the clamp and the housing)
|
Applicable Safety Rules
|
IEC1010-1, IEC1010-2-032, Pollution degree 2, CAT III (600V)
|
Accessories
|
Meter: 1 pc; Toolkit: 1pc; USB Com-cable: 1 pc; Disk: 1 pc; Battery(6F22 9V): 1 pc
|