Obciążenie AC (rezystancyjne i indukcyjne) – Kongter K-1000

Zapytaj o produkt +

Opis

Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.

Kongter has an extensive range of resistive & reactive load banks to simulate these types of loads on a power source and the transformers, relays, and switches which will distribute the power throughout your facility.

 

  • Compact AC load bank unit with user friendly control panel.
  • Effectively applied for full load test of generator set, UPS and other AC power systems.
  • Sectionalized control of input power enables any customized setting of load step and time.
  • Real-time display of test current, voltage, power, power factor, time and frequency.
  • Alternative control modes by local control of circuit breaker/push button or PC control.
  • PC software com protocol is open for data integration to customer’s IT system.
  • Emergency stop button for quick termination of AC load test.
  • Protection upon over load, over voltage, over temperature, short circuit and so on.
  • It adopts latest load element with high density power, safer and more durable.
  • Axial flow fans with big blast capacity for quick ventilation with low noise.
  • Many more customized models (resistive, inductive, capacitive or combined) available upon request

Application

  • Battery bank system
  • Energy storage system
  • Energy meter loop load test
  • Datacenter rack heat simulating
  • PV system Inverter anti-islanding test
  • Voltage regulator, rectifier aging load test
  • Genset, UPS load bank commission testing
  • AC/DC power supply, power source commission acceptance test

Standard Protections:

  • Emergency stop operation: one key stop loading
  • Over temperature alarm/protection: alarm & remove load
  • Fan interlock protection: loading available after fan activated
  • Over voltage protection: alarm & remove load

Optional Protections:

  • Blower thermal overload protection: alarm & remove load
  • Lack of air volume protection: alarm & remove load
  • Short circuit protection by fuse(over current protection)
  • Phase sequence protection(for fans with 3 phase voltage)
  • Air inlet & outlet temperature monitoring
  • Or other functions as requested

Control Modes:
Two control modes available for Kongter’s series AC load banks via local panel and PC software.

  • Local control mode by contactor or circuit breaker as requested by customer
  • PC software control (optional)
    Communication protocol of PC software is open to users for integration to their own system.